Nurse Call & Disabled
Toilet Alarms
BAFE-certified engineers with over three decades of combined experience. London and Kent. Updated September 2026
Key facts
- Compliant with HTM 08-03 and BS 8300-2
Professional Nurse Call & Disabled Toilet Alarms in London and Kent
Reliable nurse call and disabled toilet alarm systems provide essential support for safety, independence, and rapid assistance when it is needed most. Our solutions are designed to provide clear and immediate alerts, enabling staff, carers, or designated responders to quickly identify and respond to assistance requests. From healthcare and care environments to commercial and public buildings, systems can be tailored to suit the specific needs of each premises, with features such as visual and audible indicators, reset facilities, pull cords, emergency buttons, and remote notification options. By providing a dependable means of communication in an emergency, these systems help create safer, more accessible environments for everyone.
At a glance
- Nurse call systems follow HTM 08-03, NHS guidance for hospital bedhead services
- Disabled toilet alarms are governed by BS 8300-2:2018, a genuine British Standard
- BS 8300 alarms required under the Equality Act 2010 wherever an accessible toilet exists
- 100% paperless digital certificates issued via the Smartec Client Portal
- Guaranteed under-4-hour emergency dispatch, 24/7/365, for contract clients
Two related systems, two different standards
Nurse call
HTM 08-03
A Health Technical Memorandum from the Department of Health, covering hospital bedhead services including nurse call and panic alarm systems. Guidance, not a British Standard, though widely followed as best practice in care homes too.
Disabled toilet alarms
BS 8300-2:2018
A genuine British Standard for accessible and inclusive building design, driven by the Equality Act 2010. Sets specific technical requirements for the alarm itself.
What BS 8300-2 requires of a disabled toilet alarm
- A red pull cord with two 50mm diameter loops, positioned at defined heights so it can be reached from the floor
- Operable even if the person has fallen
- Both an audible and a visual alert at a staffed location
- Reset only from the point the alarm was raised, so a call cannot be cancelled without being attended
- Must never be confused, audibly or visually, with a fire alarm
Is this a legal requirement?
How Smartec does this
What does installation involve?

Site survey identifying call points, bedhead locations or accessible toilet cubicles


Installation of call points, pull cords, indicator panels and control equipment


Who needs this?
Hospitals
Nurse call to HTM 08-03, plus accessible toilet alarms throughout
Care homes
Nurse call best practice, disabled toilet alarms where accessible facilities exist
Offices & public buildings
Disabled toilet alarms required under the Equality Act 2010
Schools
Accessible facilities for pupils, staff and visitors alike
New regulation to know
The Fire Safety (Residential Evacuation Plans) Regulations 2025 (“Residential PEEPs”) come into force on 6 April 2026, introducing a duty for person-centred evacuation plans for relevant residents in certain residential buildings — a significant, recent change that most existing guidance on this topic has not yet caught up with.
Nurse Call Project
Kudos Healthcare Portfolio
Smartec provides nurse call systems across the Kudos healthcare portfolio, keeping multiple sites compliant with HTM 08-03 and tracked through the Smartec Client Portal.
Toilet Alarm Project
Pilgrims' Way Primary School
As part of an integrated life safety and security installation at Pilgrims’ Way Primary School, Smartec fitted BS 8300-2 compliant disabled toilet alarms throughout the site.
FAQs
- What is HTM 08-03?
- A Health Technical Memorandum from the Department of Health covering hospital bedhead services, including nurse call and panic alarm systems.
- Is a disabled toilet alarm a legal requirement?
- Yes, under the Equality Act 2010, wherever an accessible toilet is provided. BS 8300-2 sets the technical standard.
- What must a disabled toilet alarm pull cord look like?
- A red cord with two 50mm diameter loops, reachable from floor level, operable even if the person has fallen.
- Can a disabled toilet alarm be confused with a fire alarm?
- No. BS 8300-2 specifically requires the two to be distinguishable, both audibly and visually.
- Is HTM 08-03 mandatory in care homes?
- Not always a strict legal mandate, but widely followed as the recognised standard of good practice, and how providers demonstrate safety to the CQC.
- Where must a disabled toilet alarm be resettable from?
- Only the point where it was raised, so a call cannot be cancelled without someone attending first.